Genie GS-1930, GS-1932, GS-2632, GS-2646 and GS-3246 Scissor Lifts: Specs, Fluids, Batteries and Calibration From the Service Manual
On this page 16 sections
- Which Genie manual covers your GS scissor
- Standard batteries by model
- Battery options and pack voltage
- Hydraulic tank and system capacities
- Hydraulic oil
- Platform up and down times, one person aboard
- Drive speed and braking
- System relief valve pressure, maximum
- Checking and setting the system relief valve
- Tires and wheel fastener torque
- Tilt alarm and level sensor calibration
- Platform overload calibration load (rated load placed in the platform)
- Running the overload calibration
- Charger profiles
- Codes you will see most on a GS scissor
- Using the code table
Which Genie manual covers your GS scissor
Genie splits its current GS slab scissors across two Service and Repair Manuals, and the right one depends on the model and the serial number on the chassis label. The newest is Part No. 1321209GT, Rev B, July 2025, titled GS-32m, 32, 46, 55. Its serial chart (p.ii) covers the GS-1432m and GS-1932m (from GS32MD-9201, GS32MP-141, GS32MT-101 and GS32MV-101), the GS-1932, GS-2632 and GS-3232 (from GS32D-25101 and from GS32T-10001), the GS-2646, GS-3246 and GS-4046 (from GS46D-40101 and from GS46T-10001) and the GS-4655. The older book still on Genie's site is Part No. 1309020GT, Rev B, August 2021, titled GS-30m, 32m, 30, 32, 46, 55. It is the one that covers the GS-1930 and GS-1932 from GS30P-200101, the GS-1530 and GS-1532, the GS-2032, GS-2632 and GS-3232 from GS32D-10101 and GS32P-200101, the GS-2046, GS-2646, GS-3246 and GS-4046 from GS46D-20101, the GS-2646 XH and GS-3246 XH from GS46P-200101, and the GS-1330m and GS-4655 (p.ii). The GS-1930, GS-2032 and GS-2046 appear only in the 2021 book. Neither manual prints platform height or rated platform capacity: both say to refer to the Operator's Manual for operational specifications (p.1). Where the two books disagree for the same model name, the numbers below say which edition they come from, because the later serial ranges were changed.
Standard batteries by model
| Model | Standard batteries | Rated capacity | Manual, page |
|---|---|---|---|
| GS-1930, GS-1932 (electric drive, 2021 serials) | 4 x 6V DC, group GC2, type T-605, 58 lb each | C20 = 210AH, 383 min reserve at 25A | 1309020GT p.1 |
| GS-1930, GS-1532 and others with hydraulic drive (2021) | 4 x 6V DC, group GC2, type T-105, 62 lb each | C20 = 225AH, 447 min reserve | 1309020GT p.1 |
| GS-1932 (2025 serials) | 2 x 12V DC, group GC12, type T1275+, 85 lb each | C20 = 150AH, 280 min reserve | 1321209GT p.1 |
| GS-2632, GS-3232, GS-2646, GS-3246 (2025) | 4 x 6V DC, group GC2, type T-605, 58 lb each | C20 = 210AH, 383 min reserve | 1321209GT p.1 |
| GS-4046, GS-4655 | 4 x 12V DC, group GC12, type T1275+ (T1275 in 2021) | C20 = 150AH, 280 min reserve | 1321209GT p.1; 1309020GT p.1 |
| GS-1432m, GS-1932m | 2 x 12V DC, group 24 type 27TMH (115AH) or GC12 type T1275 (150AH) | 131 or 280 min reserve | 1321209GT p.1 |
Battery options and pack voltage
The 2021 book's electrical legend describes battery pack B5 as 24V DC, 4 each at 6V DC, for all other models, which includes the GS-1930 (p.208). The same legend lists a 24V, 2 each at 12V pack for the GS-4046, while the specification page lists a quantity of four 12V batteries for the GS-4046 and GS-4655 (p.1), so confirm the GS-4046 pack against the machine. Both books list maintenance-free (AGM) options. In the 2021 book the electric-drive option for the 6V machines is four DC224-6 batteries, 224AH, 68.3 lb each, and the hydraulic-drive option is four 6V-AGM, 200AH (p.2). The 2025 book adds a T1275AGM (132AH) and an LDC12-150-GC12 (150AH) for the GS-1932, a T105AGM (228AH) and a DC224-6 for the 6V machines, and T1275AGM or DC150-12 for the GS-4046 and GS-4655 (p.2). It also lists a 24V DC lithium iron phosphate option: one battery of 90AH (45 lb) or 100AH (56 lb) on the GS-1932, GS-2632, GS-3232, GS-2646 and GS-3246, and 150AH (89 lb) on the GS-4046 (p.3). An AGM or lithium machine has no cells to water, so check which battery is fitted before following any watering routine.
Hydraulic tank and system capacities
| Model | Hydraulic tank | System including tank | Manual, page |
|---|---|---|---|
| GS-1930, GS-1932 (electric drive, 2021) | 1.0 gal (3.8 L) | 1.46 gal (5.5 L) | 1309020GT p.3 |
| GS-1530, GS-1532, GS-1930, GS-1932 (hydraulic drive, 2021) | 3.4 gal (12.9 L) | 3.8 gal (14.2 L) | 1309020GT p.3 |
| GS-1932 (2025) | 1.5 gal (5.7 L) | 2.03 gal (7.7 L) | 1321209GT p.4 |
| GS-2032, GS-2632, GS-3232, GS-2046, GS-2646, GS-3246 (electric drive, 2021) | 4.0 gal (15.1 L) | 6.13 gal (23.2 L) | 1309020GT p.3 |
| GS-2632, GS-3232, GS-2646, GS-3246 (2025) | 4.0 gal (15.1 L) | 5.3 gal (20 L) | 1321209GT p.4 |
| GS-2032, GS-2632 (hydraulic drive, 2021) | 3.4 gal (12.9 L) | 4.5 gal (17 L) | 1309020GT p.3 |
| GS-4046 | 4.9 gal (18.5 L) in 2021; 5.3 gal (20 L) in 2025 | 7.84 gal (29.7 L) in 2021; 7.03 gal (26.6 L) in 2025 | 1309020GT p.3; 1321209GT p.4 |
| GS-4655 | 5.9 gal (22.4 L) | 7.94 gal (30 L) | both, p.3 and p.4 |
Hydraulic oil
Both books name Chevron Rando HD Premium, grade 32, viscosity index 200, as the recommended fluid, with a minimum cleanliness level of ISO 15/13 and a maximum water content of 250 ppm (1321209GT p.6; 1309020GT p.5). Approved optional fluids are Shell Tellus S2 V 32, S2 V 46 and S4 VX 32, Shell Donax TG (Dexron III) and Chevron 5606A (mineral based), Petro Canada Environ MV 46 (biodegradable) and UCON Hydrolube HP-5046 (fire resistant). Genie says the optional fluids need additional equipment and special installation instructions and to consult Genie Product Support before use. The manual warns not to top off with incompatible fluids, because mixing can form insoluble deposits that plug lines, filters and valves. If fluid temperature consistently exceeds 200 F (90 C) an optional oil cooler may be needed, and the machine should not be run when ambient air is consistently above 120 F (49 C) (p.6). Cold weather: a hydraulic oil heating system is recommended when ambient is consistently below 0 F (-18 C), the machine should not be run below -20 F (-29 C) on Rando HD Premium MV, and Chevron 5606A or equivalent is required when ambient is consistently below 0 F (-17 C) unless an oil heater is used. Continued use of 5606A when ambient is consistently above 32 F (0 C) may damage components (1321209GT p.7). The return filter on every model is 10 micron (pp.9-10).
Platform up and down times, one person aboard
| Model | Platform up | Platform down | Manual, page |
|---|---|---|---|
| GS-1930 (electric drive) | 21 to 26 s | 18 to 22 s | 1309020GT p.4 |
| GS-1932 (2025) | 25 to 33 s | 24 to 30 s | 1321209GT p.5 |
| GS-2032 | 34 to 41 s | 23 to 33 s | 1309020GT p.4 |
| GS-2046 | 34 to 41 s | 26 to 34 s | 1309020GT p.5 |
| GS-2632 (2025) | 36 to 43 s | 27 to 37 s | 1321209GT p.5 |
| GS-3232 (2025) | 50 to 58 s | 26 to 33 s | 1321209GT p.5 |
| GS-2646 (2025) | 40 to 48 s | 22 to 30 s | 1321209GT p.5 |
| GS-3246 (2025) | 58 to 65 s | 26 to 34 s | 1321209GT p.5 |
| GS-4046 (2025) | 71 to 79 s | 35 to 45 s | 1321209GT p.5 |
Drive speed and braking
The 2025 book gives a maximum stowed drive speed of 2.5 mph (4 km/h), timed at 40 ft in 10.9 seconds. With the platform raised the limit is 0.5 mph (40 ft in 55 seconds) on the GS-32 models and 0.3 mph (40 ft in 91 seconds) on the GS-46 models. Maximum braking distance in high range on a paved surface is under 1.3 ft (0.4 m) (p.5). The 2021 book gives the same 2.5 mph stowed and 0.5 mph raised figures for the GS-1930 class, 2.0 mph stowed (40 ft in 13.6 seconds) for the hydraulic-drive GS-2032 and GS-2632, and a braking distance under 1 ft (0.3 m) (p.4). Gradeability is in the Operator's Manual. The GS-3232 outriggers level the machine up to 5 degrees side to side and 3 degrees front to rear (both books).
System relief valve pressure, maximum
| Model | 2025 book (1321209GT p.9-10) | 2021 book (1309020GT p.9-11) | Note |
|---|---|---|---|
| GS-1930, GS-1932 | GS-1932: 3300 psi (228 bar) | Electric drive 3500 psi (241 bar); hydraulic drive 3700 psi (255 bar) | GS-1932 gear pump 0.092 cu in per rev |
| GS-2032 | not covered | 2400 psi (165 bar) electric drive | Hydraulic drive GS-2032/2632: 3500 psi |
| GS-2632 | 2000 psi (138 bar) | 2100 psi (145 bar) electric drive | |
| GS-3232 | 2300 psi (159 bar) | 2300 psi (159 bar) | Outrigger manifold: 2300 psi (2025), 3500 psi (2021) |
| GS-2046 | not covered | 2900 psi (200 bar) | |
| GS-2646 | 2700 psi (186 bar) | 2800 psi (193 bar) | |
| GS-3246 | 2300 psi (159 bar) | 2600 psi (179 bar) | |
| GS-4046 | 2100 psi (145 bar) | 2350 psi (162 bar) | |
| GS-4655 | 2900 psi (200 bar) | 2900 psi (200 bar) |
Checking and setting the system relief valve
The two editions print different maximums for several of the same model names, so set the valve to the figure in the manual that matches your serial number. The 2025 procedure (section 5-6, p.50): confirm the hydraulic oil is at the FULL mark, park on a firm, level surface with the platform empty and nothing overhead, and connect a 0 to 5000 psi (0 to 350 bar) gauge to the test port on the function manifold. Turn the key to ground control, pull out both red Emergency Stop buttons, fully raise the platform from the ground controls and keep holding platform up while you read the gauge. To adjust, turn the key off, hold the valve stem with a hex key, loosen the jam nut, turn the stem clockwise to raise or counterclockwise to lower the pressure, tighten the jam nut and repeat the test to confirm.
Tires and wheel fastener torque
| Models | Tire (solid rubber) | Wheel fastener torque | Manual, page |
|---|---|---|---|
| GS-1530, GS-1532, GS-1930, GS-1932 | 12 x 4.5 in (30.5 x 11.4 cm) | Castle nut 300 ft-lb (406.7 Nm) dry, 225 ft-lb (305 Nm) lubricated | 1309020GT p.3; 1321209GT p.4 |
| GS-1432m, GS-1932m | 10 x 3 in | Castle nut 200 ft-lb (271.2 Nm) dry, 150 ft-lb (203.4 Nm) lubricated | 1321209GT p.4 |
| GS-2632, GS-3232, GS-2646, GS-3246 (2025) | 15 x 5 in (38.1 x 12.7 cm) | Castle nut 300 ft-lb dry, 225 ft-lb lubricated | 1321209GT p.4 |
| GS-3246 (AUS), GS-4046, GS-4655 (2025) | 15 x 5 in | Hex head cap screw 90 ft-lb (122 Nm) dry, 80 ft-lb (108.5 Nm) lubricated | 1321209GT p.4 |
| GS-2032 to GS-4655 with electric drive (2021) | 15 x 5 in | Hex head cap screw 90 ft-lb dry, 80 ft-lb lubricated | 1309020GT p.3 |
Tilt alarm and level sensor calibration
The ground control module cuts out lift and drive and sounds an alarm when the level sensor reports a tilt beyond 1.5 degrees side to side or 3 degrees front to rear on every GS model in these books except the GS-1330m, which is 1.5 and 2.5 degrees (1309020GT p.35; 1321209GT p.33). After a new level sensor is fitted the ground controls show C051: SYSTEMFAULT, TILT:NoCal (1321209GT p.34). To calibrate, work on a surface you have checked with a digital level, raise the platform 7 to 9 ft (2.1 to 2.8 m), about 13 ft (4 m) on the GS-4655, and lower it onto the safety arm. Install the sensor with the Y toward the ground controls side and the X toward the non-steer end. Power up the ground controls with the scroll up and scroll down buttons held, go to Select Option, then Tilt Sensor, and press and hold Enter until the alarm confirms. The machine will not calibrate on a slope of one degree or more (p.35). Genie's danger note: a level sensor installed other than as specified compromises stability and can tip the machine over.
Platform overload calibration load (rated load placed in the platform)
| Model | Load, 2025 book (p.118) | Load, 2021 book (p.159) |
|---|---|---|
| GS-1930 | not covered | 500 lb (227 kg) |
| GS-1932, GS-2632, GS-3232 | 500 lb (227 kg) | 500 lb (227 kg) |
| GS-2032 | not covered | 800 lb (363 kg) |
| GS-2046 | not covered | 1200 lb (544 kg) |
| GS-2646 | 1000 lb (454 kg) | 1000 lb (454 kg) |
| GS-3246 | 700 lb (317 kg) | 700 lb (317 kg) |
| GS-4046 | 700 lb (317 kg) | 770 lb (350 kg) |
| GS-4655 | 770 lb (350 kg) | 770 lb (350 kg) |
Running the overload calibration
Ambient temperature must be above 32 F (0 C). If a new ground controller is installed, the Full Load Calibration is required to keep rated platform capacity; a No Load Calibration alone significantly reduces lifting performance (1321209GT p.118). The GS-1932, GS-2632, GS-3232, GS-2646, GS-3246 and GS-4046 offer Full Load, No Load and No Lift calibrations. Before a full load run: fully charge the batteries, check the hydraulic fluid is between the FULL and ADD marks, apply a thin layer of dry film lubricant where the scissor arm wear pads touch the chassis, chock both sides of the steer-end wheels and secure the rated load from the table in the platform. Power up the ground controls holding Menu Up and Menu Down, then go to Select Option, Platform Overload, Platform Overload Calibrate, Full Load, and follow the LCD prompts as the machine raises, stops to gather data and lowers (pp.118-119). Indoor-only models should be calibrated where the platform can be fully raised; outdoors only in winds under 28 mph (12.5 m/s), deck extension retracted and with flat weights secured (p.117). For frequent nuisance trips after calibrating a GS-3232, Genie recommends recalibrating full load and no load with 250 kg in the platform (p.118).
Charger profiles
The onboard charger stores several charge profiles and must be set to match the batteries on the machine (2021 p.170; 2025 p.129). Profiles in the 2021 book: P001 flooded lead acid, temperature compensated; P003 flooded lead acid, not temperature compensated (neither for the GS-4046 or GS-4655); P007 flooded lead acid for the GS-4046 and GS-4655; P043 AGM, temperature compensated, all scissor models (p.171). The 2025 book keeps P001, P003 and P007 and lists P316 for AGM and P341 for the lithium battery on GS32 and GS46 models (p.130). Temperature compensated means a battery temperature sensor is installed. To select: key off and ground Emergency Stop in, open the battery compartment, hold the profile button while plugging the charger into AC until the amber error light is on and the green charging light flashes, step to the right profile, then hold the button until the error and charging lights go out and the AC light comes on. Profile mode exits after 15 seconds of inactivity.
Codes you will see most on a GS scissor
| Code | Shown as | What the manual says | Page |
|---|---|---|---|
| LL | Status code (OIC) | Off-Level. A status indicator, not a device malfunction. | 1309020GT p.181; 1321209GT p.140 |
| OL | Status code (OIC) | Platform Overload. | 1309020GT p.181; 1321209GT p.140 |
| CHrg | Status code (OIC) | Charger interlock: charger connected to AC, functions limited. Unplug the charger to clear. | 1309020GT p.181 |
| P037 | PO37:BATTERY OUT OF RANGE | Battery voltage out of range at startup. Causes: voltage sensor circuit, low batteries, faulty battery, charger plugged into AC, DCON ECM. All functions inhibited. | 1309020GT p.191; 1321209GT p.150 |
| C025 | C025:SYSTEMFAULT PLAT OVLD:NOCAL | Platform overload system not calibrated. All functions inhibited. | 1321209GT p.162 |
| F034 | F034:SENSORFAULT OVLD:PLAT HEIGHT | Height sensor stowed and maximum height settings not calibrated. All functions inhibited. | 1321209GT p.160 |
| U037 | U037:SWITCHFAULT FOOTSW PRESSED | Foot switch pressed at machine startup. All functions inhibited. | 1321209GT p.156 |
| C058 | C058:DCON ECM Fault Type 04 | Drive controller voltage out of range: charger connected to AC, batteries too low, or DCON ECM. | 1321209GT p.163 |
| E-0-0-2 | Charger error | Low battery voltage detected before the charge cycle. Check voltage, cables and battery condition. | 1309020GT p.203 |
| E-0-0-3 | Charger error | Charge timeout: pack did not reach voltage in the safe time. Disconnect the pack for 30 seconds to clear once corrected. | 1309020GT p.203 |
Using the code table
Genie's GS scissors use the Genie SmartLink Diagnostic System: two-to-four letter Operational Indicator Codes for machine status, and letter-plus-three-digit Diagnostic Trouble Codes for faults, H for hydraulic devices, P for power devices, U for user interface, F for feedback devices such as sensors, and C for controls (1309020GT p.182). Both appear at the platform and ground controls, and the ground control LCD adds a short description. The 2025 book adds a block of P, F and C codes for lithium-battery machines. The full lists, including the other OIC codes, are on the Genie fault codes page linked below.
Frequently Asked Questions
What batteries does a Genie GS-1930 use?
On the electric-drive GS-1930 the 2021 Service and Repair Manual lists four 6V DC GC2 batteries, type T-605, C20 rating 210AH, 58 lb each, forming a 24V pack. The maintenance-free option is four DC224-6 AGM batteries. Hydraulic-drive machines use four 6V T-105 batteries, 225AH (1309020GT pp.1-2, 208).
How much hydraulic oil does a Genie GS-1930 hold?
With electric drive the tank holds 1.0 gal (3.8 L) and the whole system 1.46 gal (5.5 L). With hydraulic drive the tank holds 3.4 gal (12.9 L) and the system 3.8 gal (14.2 L) (1309020GT p.3).
What hydraulic oil goes in a Genie GS scissor lift?
Genie recommends Chevron Rando HD Premium, grade 32, with ISO 15/13 minimum cleanliness. Approved alternatives include Shell Tellus S2 V 32 and Chevron 5606A for cold climates, but do not top off with an incompatible fluid (1321209GT p.6).
Which service manual do I need for my GS-2632 or GS-3246?
Check the serial number. From GS32D-25101 or GS32T-10001 (GS-2632, GS-3232) and from GS46D-40101 or GS46T-10001 (GS-2646, GS-3246, GS-4046) use Part No. 1321209GT, July 2025. Earlier GS32 and GS46 machines are in Part No. 1309020GT, August 2021. Relief pressures differ between them.
What weight do I use to calibrate the overload system on a GS-2646 or GS-3246?
Both editions list 1000 lb (454 kg) for the GS-2646 and 700 lb (317 kg) for the GS-3246, secured in the platform, with the batteries fully charged and ambient above 32 F (1321209GT p.118; 1309020GT p.159).
Sources
Documents this guide was checked against. How we verify.
- Genie Service and Repair Manual, GS-32m, 32, 46, 55 (GS-1432m, GS-1932m, GS-1932, GS-2632, GS-3232, GS-2646, GS-3246, GS-4046, GS-4655; serial chart p.ii), Rev B July 2025, Part No. 1321209GT: specifications pp.1-11; level sensors pp.33-35; relief valve p.50; platform overload calibration pp.117-119; battery charger pp.129-130; OIC and DTC charts pp.140-166
- Genie Service and Repair Manual, GS-30m, 32m, 30, 32, 46, 55 (incl. GS-1930/1932 from GS30P-200101, GS-2032/2632/3232, GS-2046/2646/3246/4046 from GS46D-20101; serial chart p.ii), Rev B August 2021, Part No. 1309020GT: specifications pp.1-11; level sensors p.35; overload calibration p.159; battery charger pp.170-171; OIC p.181; DTC types p.182; P codes p.191; charger error codes p.203; electrical legend p.208