JLG 1930ES, 2032ES, 2632ES, 2646ES and 3246ES: Specs, Service and Battery Care From the Service Manual

Heavy equipment JLG 9 min read Updated 2026-11-20
On this page 22 sections
  1. What the manual covers
  2. Heights and rated capacity (ANSI/CSA)
  3. Notes on the capacity and height figures
  4. Weight, speed and size
  5. Other operating specifications
  6. Hydraulic fluid capacities
  7. Hydraulic oil and lubricants
  8. Checking and changing the hydraulic oil
  9. Torque values and relief pressures
  10. Spindle nut procedure
  11. Inspection schedule
  12. Drift test
  13. Battery care
  14. Battery chargers listed in the manual
  15. Charger care and algorithm
  16. Charger fault LED flashes
  17. Excess watering or a rotten egg smell
  18. Tilt settings and high drive cutout
  19. Tilt sensor calibration
  20. Elevation sensor calibration
  21. Codes you will see most on these scissors
  22. Reading the codes

What the manual covers

Everything on this page comes from the JLG Service and Maintenance Manual for the 1930ES, 2032ES, 2632ES, 2646ES and 3246ES, publication 3121656, Rev I dated January 24, 2025. The cover lists serial ranges starting 0200239382, 1200025021 and M200000100 with fixed end numbers, and B200020297 to present for all five models. The 2646ES and 3246ES coverage excludes PVC 1910, PVC 2004 and PVC 2104 machines. These are 24-volt DC machines: the DTC section says they run on four 6-volt batteries in series (p.6-1). The nameplate at the left rear tells you where the machine was built: a serial number starting 02 is USA built and one starting B2 is China built, which matters for the lift relief setting (p.1-7).

Heights and rated capacity (ANSI/CSA)

ModelMax platform heightWorking heightMax capacity, ANSI/CSA
1930ES18.75 ft (5.7 m)25 ft (7.6 m)500 lb (227 kg), 2 persons
2032ES20 ft (6 m)26 ft (7.9 m)800 lb (363 kg), 2 persons
2632ES25.6 ft (7.8 m)32 ft (9.8 m)500 lb single capacity; dual capacity 800 lb to 20 ft, 500 lb to 26 ft
2646ES26 ft (7.9 m)32 ft (9.8 m)1000 lb (454 kg), 2 persons
3246ES31.8 ft (9.7 m)38 ft (11.6 m)1000 lb (454 kg) to 26 ft (Zone A); 700 lb (317 kg) to 32 ft (Zone B)

Notes on the capacity and height figures

Heights are from Table 1-11 (p.1-5) and capacities from Table 1-2 (p.1-2). Every platform extension is rated 250 lb (120 kg). CE and Australian outdoor ratings are much lower than indoor ones: for example the 1930ES is 230 kg with 2 persons indoors but 120 kg with 1 person outdoors, and the 2632ES has no CE or Australian outdoor rating at all. The manual gives two different heights for the 2632ES: 25.4 ft (7.75 m) in the operating specifications (Table 1-1, p.1-1) and the tilt table, and 25.6 ft (7.8 m) in the dimensions table (p.1-5). Maximum wind speed is 28 mph (12.5 m/s), depending on model, market and indoor or outdoor selection (p.1-1).

Weight, speed and size

ModelGross weight (ANSI/CSA)Max drive speedWidth x length (deck retracted)
1930ES2825 lb3 mph (4.8 km/h)2.5 ft x 6 ft
2032ES3610 lb3 mph (4.8 km/h)2.66 ft x 7.5 ft
2632ES4635 lb (single), 4610 lb (dual)2.75 mph (4.4 km/h)2.66 ft x 7.5 ft
2646ES4975 lb2.5 mph (4 km/h)3.7 ft x 8.2 ft
3246ES5025 lb2.5 mph (4 km/h)3.7 ft x 8.2 ft

Other operating specifications

All five models are rated for 25% gradeability and 5 degrees side slope when stowed. Elevated drive speed is 0.5 mph on every model, timed at 28 to 37 seconds over 25 ft (Table 1-10, p.1-5). Tires are 323 mm x 100 mm on the 1930ES and 406 mm x 125 mm on the other four, with a maximum tire load of 2500 lb and 4000 lb respectively (Table 1-4, p.1-3). The drive motor is a shunt wound Sepex 24V DC motor, 0.65 hp at 3750 rpm, and the hydraulic pump motor is a 24V DC permanent magnet unit rated 3 kW (p.1-3). Unloaded lift-up times run from 18 to 26 seconds on the 1930ES to 50 to 62 seconds on the 3246ES (Table 1-9, p.1-4).

Hydraulic fluid capacities

ModelHydraulic tankSystem including tank
1930ES2 gal (7.6 L)2.2 gal (8.3 L)
2032ES, 2632ES2 gal (7.6 L)2.8 gal (10.6 L)
2646ES, 3246ES3 gal (11.3 L)5.3 gal (19.9 L)

Hydraulic oil and lubricants

The manual's hydraulic oil note asks for anti-wear qualities at least to API GL-3 and names Mobil DTE 11M, and says not to mix brands or types (p.1-6). Viscosity by system operating temperature: 10W for 0 to +23 F, 10W-20 or 10W-30 for 0 to 210 F, and 20W-20 for 50 to 210 F (Table 1-13). Specifications are also printed for Mobil DTE 10 Excel 15 and for two biodegradable fluids, Mobil EAL Envirosyn H 32 and Mobil SHC Hydraulic EAL 32 (p.1-7). Grease is MPG, a multipurpose extreme pressure grease with a minimum dripping point of 350 F, and gear lube is EPGL to API GL-5 or MIL-L-2105 (Table 1-14). The manual says not to start the hydraulic system below -15 F (-26 C) without heating the oil (p.2-4). The drive torque hubs hold 10 oz of oil each: fill with ISO grade 68 hydraulic oil (80W gear oil or 20W engine oil) and check the level with the plugs at 12 and 3 o'clock; oil at the 3 o'clock plug means the level is right (p.3-4).

Checking and changing the hydraulic oil

The manual says to check the hydraulic oil level every 6 months and any time maintenance could have affected it (section 4.6, p.4-5). With the machine level and the platform empty, raise the platform, swing out the safety prop, and keep raising until the fill plug on the right side of the tank (attached to the lift cylinder) is accessible. The 2632ES, 2646ES and 3246ES have to go higher than the 1930ES and 2032ES. Clean the area, remove the plug slowly to vent pressure (the manual warns there may be up to 10 psi in the tank), then lower the arms onto the safety prop. The oil should be completely full, at the top of the fill port. Add oil until it weeps out, and torque the plug to 40 ft lb (56 Nm). On changes, p.2-4 says the filter elements must be changed annually unless operating in extreme conditions, and that JLG recommends changing the hydraulic oil annually; always replace the filter and clean the magnet when the oil is changed.

Torque values and relief pressures

ItemValueWhere printed
Rear wheel spindle nut (dry)30-40 ft lb (40-54 Nm), check every 50 hoursTable 1-12, p.1-6
Wheel bolts (dry)105-120 ft lb (142-163 Nm), check every 50 hoursTable 1-12, p.1-6
Hydraulic tank fill plug40 ft lb (56 Nm)p.4-5
Lift relief, 1930ES and 2032ES, USA built1800 psi +/- 50 (124 bar)Table 1-17, p.1-7
Lift relief, 2632ES, USA built1950 psi +/- 50 (134 bar)Table 1-17, p.1-7
Lift relief, 2646ES and 3246ES, USA built2000 psi +/- 50 (138 bar)Table 1-17, p.1-7
Lift relief, all models, China built1900 psi +/- 50 (131 bar)Table 1-17, p.1-7
Steer relief, all models1500 psi (103 bar)Table 1-17, p.1-7

Spindle nut procedure

After torquing the rear spindle nut, the manual says to loosen it completely until it turns by hand, finger tighten it without rotating the hub, and back it off if needed to line up the cotter pin slot (p.1-6). Self-locking nuts are not to be reused. When a wheel bolt is replaced, use one of the same length (M12-1.5 x 32-36 mm on wheels that use the 1/4 inch ring).

Inspection schedule

Section 2 sets four inspections (Table 2-1, p.2-2). The Pre-Start Inspection is the operator's job before use each day or at each change of operator. The Pre-Delivery Inspection is done before each sale, lease or rental delivery. The Frequent Inspection is due for a machine in service for 3 months or 150 hours, whichever comes first, out of service for more than 3 months, or purchased used (p.2-1). The Annual Machine Inspection is due no later than 13 months from the prior one, and the manual notice says JLG requires it to be done on the Annual Machine Inspection Report form (p.2-6). Table 2-3 (p.2-7) lists the same check codes for the frequent and annual inspections: for example battery 3,5 (fluid level, leakage), lift cylinder 1,4,5,6,12,13, wheel and tire assemblies 1,8,9, and lanyard anchorage 1,4,16. The hydraulic filter row shows code 26, which is not in the 1-16 code list printed on p.2-6.

Drift test

With the platform fully elevated, the maximum allowed platform drift is 2 inches (5 cm) in 10 minutes. If the machine fails, measure drift at the cylinder rod with a calibrated dial indicator, oil at ambient temperature and normal platform load, against Table 2-2: for a 3 inch bore the limit is 0.026 in (0.66 mm) in 10 minutes, and for a 4 inch bore 0.015 in (0.38 mm) (section 2.4, p.2-5). The lift cylinder bores are 2.8 in on the 1930ES, 3.1 in on the 2032ES and 2632ES, and 3.9 in on the 2646ES and 3246ES (Table 1-20, p.1-9).

Battery care

The manual's battery practices are on p.3-29. Check electrolyte often and add only distilled water, from a non-metallic container or funnel. When fully charged, the fluid should be 1/8 inch below the vent tubes. Do not fill to the bottom of the vent tubes, and do not let the level fall below the top of the plates while charging or operating. Charge only in a well ventilated area with no flames or sparks, and neutralize acid spills with baking soda and water. The batteries count as stability weight: each 220 amp battery weighs 60 lb (27 kg), a 220 amp battery used with the inverter/charger 66 lb (30 kg), and a 245 amp battery 70 lb (32 kg, not listed for the 1930ES), and the manual warns not to replace them with batteries of a different weight or specification (Table 1-22, p.1-9). The batteries sit on a roll-out door; to remove it, pull the door out, disconnect the batteries, support the door on forks or a lifting device, and remove the door rollers at the rear corners (section 3.8, p.3-28). Machine setup has a battery setting, FLOODED or AGM, so the control system knows which type is fitted (Table 5-4, p.5-28).

Battery chargers listed in the manual

ChargerDC outputAC input
Delta-Q 100111211124V nominal, 33.6V max, 25A85-265 VAC, 45-65 Hz
Eagle Performance 100117784224V nominal, 31.92V max, 25A108-132 VAC
Green Power 100121859524V nominal, 34V max, 30A100-240 V, 8.5A max
Xantrex charger/inverter 1001093839 (option)28 VDC nominal, 33 VDC max, 23-27A100-130 VAC; inverter 1000 W continuous

Charger care and algorithm

The Delta-Q charger sits on top of the chassis at the rear; raise the arms and set the arm prop to reach it (p.3-29). The manual's charger maintenance points: check the water in each cell of flooded batteries after charging, keep the charger-to-battery connections tight and clean, and keep the charger away from oil and direct heavy water spray (p.3-30). It warns never to charge a frozen battery and to use the charger only with an algorithm that suits the battery type. The charger shows its algorithm number on the yellow LED for about 11 seconds whenever AC is applied with the battery pack disconnected. To change it, touch the charger's positive connector to the battery positive terminal for 3 seconds during that window to advance one step, and when the right number shows, hold it on the terminal until the output relay clicks (about 10 seconds) to store it (p.3-32). Table 3-2 lists algorithm 23 as the JLG default for Douglas flooded batteries and several golf-cart style flooded batteries, 43 for the Harris Discover EVGC6A-A AGM, and 35 for JLG part number 0400242. A new battery pack that differs from the old one needs the algorithm changed. The manual also notes that non-approved batteries can cause charger fault codes (p.1-3).

Charger fault LED flashes

FlashesMeaningWhat the manual says to check
No lightsNo AC power, AC too low, or internal failureCheck for 90 to 260 VAC at the charger; if present and still no lights, return the charger for service
1High battery voltageCharger voltage matches pack voltage; wiring; other charging sources. Clears by itself
2Low battery voltageBattery failure or no battery connected; battery connections; nominal voltage. Clears by itself
3Charge time-outShorted cells, low water, connections, AC supply. Clear by unplugging AC for 30 seconds
4Check battery: pack could not be trickle charged to the minimum levelReversed or wrong module connections, shorted cells; pack is likely in poor condition
5Over temperatureMove to a cooler place, clean dirt or mud from the cooling fins with low pressure only. Clear by unplugging AC for 30 seconds
6Over load / over temperatureBattery connections, open cell, low water; internal fuse (check green to red wire with an ohmmeter, AC off)

Excess watering or a rotten egg smell

The manual reads these as over-charging or high battery temperature, most likely from the wrong charge algorithm or high ambient temperature rather than too much charge current. It says to confirm the pack is not too small (usually over 50 Ah), that nominal battery voltage matches the charger, and that the algorithm is correct (p.3-32). The optional Xantrex charger/inverter uses the same fault LED flash codes (section 3.10, p.3-33).

Tilt settings and high drive cutout

ModelTilt front to backTilt side to side: max deck elevationHigh drive cutout height
1930ES3 degrees1.5: 18.75 ft; 2: 14 ft; 2.5: 11 ft; 3: 9 ft54 in (1.4 m)
2032ES3 degrees1.5: 20 ft; 2: 15 ft; 2.5: 12 ft; 3: 10 ft66 in (1.7 m)
2632ES3 degrees1.5: 25.4 ft; 2: 20 ft; 2.5: 16 ft; 3: 13 ft76 in (1.9 m)
2646ES3 degrees2: 26 ft; 2.5: 22 ft; 3: 20 ft76 in (1.9 m)
3246ES3 degrees2: 31.75 ft; 2.5: 22 ft; 3: 20 ft76 in (1.9 m)

Tilt sensor calibration

The tilt sensor lives in the ground control box, and the manual requires recalibration any time that box is removed (p.3-37) or the sensor is replaced (p.3-38). Park stowed on level ground; the calibration cannot run if the main contactor is open because of an alarm. In Access Level 1 on the analyzer, go to CALIBRATION, TILT SENSOR, LEVEL VEHICLE. The right arrow shows the raw readings; if either reads 5.0 degrees or more the software will not calibrate, and the manual says to check the machine and grade, the box mounting, and the sensor itself (each axis should read within 2.0 degrees when levelled on its own; replace it if not) (section 5.3, p.5-5). A reading of +20.0 degrees means an electrical fault in the sensor, board or connections. On a truly level surface the analyzer tilt angle should read within 0.5 degrees both ways, and lift cutout heights within 6 inches of the table are acceptable (p.5-7). Japanese machines labelled Ministry of Labor Notification #70 use 5 degrees regardless of height.

Elevation sensor calibration

With the machine stowed on level ground, connect the analyzer at the ground station, go to Access Level 1, CALIBRATION, SET ELEV SENSOR and press Enter (section 5.6, p.5-8). Check it by raising the arms from the platform and driving until the drive speed cuts back, then compare with the high drive cutout heights above. The analyzer shows the elevation angle sensor voltage under DIAGNOSTICS, ELEV SENSOR; it should rise from about 0.2-0.8 V to 3.6-4.2 V as the platform goes up (p.5-6). After a ground module software update, the manual says to change the model number and market in Machine Setup to another value and straight back so the settings carry over (p.5-8). Note that the DTC tables refer to tilt calibration as section 5.2 and elevation calibration as section 5.5; in this revision they are sections 5.3 and 5.6.

Codes you will see most on these scissors

DTCMessageWhat the manual says
003ALARM SOUNDING - TILTED & ABOVE ELEVATIONLower and move to level ground; check ground box mounting, pothole switches and elevation sensor; recalibrate (p.6-4)
005DRIVE & LIFT UP PREVENTED - TILTED & ELEVATEDSame checks as 003; drive and lift up are prevented (p.6-5)
008FUNCTIONS LOCKED OUT - SYSTEM POWERED DOWNLow-power state after 2 hours without activity; power cycle and check the batteries (p.6-5)
252ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATEDCalibrate the elevation angle sensor (p.6-9)
253DRIVE PREVENTED - CHARGER CONNECTEDUnplug the charger; check the CHARGER INTERLOCK setting and the interlock signal to ground board J1-29 (p.6-9)
255PLATFORM OVERLOADEDRemove excess weight, check the platform is not caught, clear CAN faults first; LSS manual 3124288 (p.6-9)
441BATTERY VOLTAGE TOO LOW - SYSTEM SHUTDOWNBattery voltage dipped under 14.5 V; recharge, check for damaged batteries and the charger (p.6-15)
811TILT SENSOR NOT CALIBRATEDCalibrate the tilt sensor, or replace and calibrate it (p.6-20)

Reading the codes

Section 6 applies to machines with the MDI (Multifunction Digital Indicator) display and a SEVCON power module with ground board software P1.13 or higher, or a ZAPI power module with P1.0 or higher. Machines without the MDI report flash codes and help messages instead, listed in Table 5-2 starting on p.5-9. The first two digits of a DTC are its flash code group, and with several DTCs active the manual says to start with the one whose first two digits are higher. After a correction, cycle power with the emergency stop (p.6-1). The general JLG fault code guide explains the numbering across JLG machines.

Frequently Asked Questions

What is the weight capacity of a JLG 1930ES?

The service manual rates the 1930ES at 500 lb (227 kg) with 2 persons under ANSI/CSA, and 250 lb (120 kg) on the platform extension. CE and Australian outdoor use drops it to 120 kg with 1 person (Table 1-2, p.1-2).

How high does a JLG 3246ES go?

Maximum platform height is 31.8 ft (9.7 m) and working height is 38 ft (11.6 m). Capacity is 1000 lb up to 26 ft (Zone A) and 700 lb up to 32 ft (Zone B) under ANSI/CSA (Tables 1-2 and 1-11).

What hydraulic oil does a JLG ES scissor lift use?

The manual names Mobil DTE 11M and asks for anti-wear quality at least to API GL-3. Grade by operating temperature: 10W-20 or 10W-30 covers 0 to 210 F. The 2646ES and 3246ES hold 5.3 gal in the system, the 2032ES and 2632ES 2.8 gal, and the 1930ES 2.2 gal (pp.1-2 and 1-6).

How often should the batteries be watered?

The manual says to check electrolyte often and add only distilled water, so that a fully charged battery sits 1/8 inch below the vent tubes. For flooded batteries it says to check each cell after charging (pp.3-29 and 3-30).

Where do I get the JLG 1930ES service manual?

It is JLG publication 3121656, available from JLG's Online Express technical publications library. Match the edition to the serial number on the nameplate at the left rear of the machine.

Sources

Documents this guide was checked against. How we verify.

Related Guides