Which manual covers your Z boom

Genie publishes a separate Service and Repair Manual for each power type, and they differ more than the model names suggest. Z-45/25 and Z-45/25J IC (engine powered): Part No. 1312350GT, Rev A, July 2021, from serial Z4525D-4536. Z-45/25J DC (battery): Part No. 1315848GT, Rev A, May 2022, from Z4525F-62000, Z4525M-9727 and Z4525D-3978. Z-45/25 and Z-45/25J Bi-Energy Power (batteries plus a small engine-driven generator): Part No. 1268546GT, Rev A4, August 2023, whose cover lists several serial ranges including Z4525N-57200 to Z4525N-58604 and from Z4525F-58605, Z4525D-940 and Z4525M-6700. Z-60 DC and Z-60 FE, the battery and hybrid versions of the Z-60/37: Part No. 1307785GT, Rev C, June 2024, from Z60H-2548, Z60M-1000 and Z60D-101. The manual itself titles these machines Z-60 DC and Z-60 FE. No diesel Z-60/37 service manual is covered here. None of these books prints platform height, outreach or rated capacity: each refers you to the Operator's Manual for operational specifications, and to the Maintenance Manual for scheduled maintenance.

Tires and lug nut torque

ModelTirePressureLug nut torque
Z-45/25 IC (1312350GT p.1)Rough terrain 315/55 D20, 12 ply; hi-flotation option 33/16LL500, 10 ply60 psi (4.1 bar) rough terrain; 38 psi (2.6 bar) hi-flotation9 lugs, 5/8-18: 125 ft-lb (169.5 Nm) dry, 94 ft-lb (127.4 Nm) lubricated
Z-45/25J DC (1315848GT p.1)9-14.5 LT, tread 8 ply, sidewall 6 plynot printed9 lugs, 5/8-18: 110 ft-lb (149 Nm) dry, 83 ft-lb (112.5 Nm) lubricated
Z-45/25 Bi-Energy (1268546GT p.1)9-14.5 LT, tread 8 ply, sidewall 6 plynot printed9 lugs, 5/8-18: 110 ft-lb (149 Nm) dry, 83 ft-lb (112.5 Nm) lubricated
Z-60 DC and FE (1307785GT p.1)355/55D625, 14 ply, foam filled, 426 lb (193 kg) minimumfoam filled9 lugs, 5/8-18: 240 ft-lb (325 Nm) dry, 180 ft-lb (244 Nm) lubricated

Fuel, hydraulic and hub capacities

ModelFuel tankHydraulic tank / system incl. tankDrive hubs / turntable drive hub
Z-45/25 IC17 gal (64.4 L); LPG 33.5 lb (15.2 kg)22 gal (83 L) / 30 gal (113.6 L)24 fl oz (710 cc) / 25.5 fl oz (750 cc)
Z-45/25J DCnone8 gal (30.3 L) / 11 gal (41.6 L)EW1 type 17 fl oz (503 cc), W1 type 23 fl oz (680 cc) / 25.5 fl oz (750 cc)
Z-45/25 Bi-Energy9 gal (34.1 L)8 gal (30.3 L) / 11 gal (41.6 L)EW1 type 17 fl oz, W1 type 23 fl oz / 25.5 fl oz (750 cc)
Z-60 DC and FE17 gal (64.4 L)18 gal (68 L) / 21 gal (80 L)24 fl oz (710 cc) / 43 fl oz (1262 cc)

Oils and drive hub types

Every Z book specifies SAE 90 multipurpose hypoid gear oil, API GL5, for the drive hubs and turntable rotation hub. On the DC and Bi-Energy Z-45/25 the drive hub capacity depends on the hub type, so read the tag on the hub (EW1 or W1) before filling (1315848GT p.1; 1268546GT p.1). The hydraulic fluid in all four books is Chevron Rando HD Premium, grade 32, viscosity index 200, minimum cleanliness ISO 15/13 and maximum water content 250 ppm, with the same optional fluids Genie lists for its other lifts (Shell Tellus S2 V 32 and V 46, S4 VX 32, Donax TG, Chevron 5606A, Petro Canada Environ MV 46, UCON Hydrolube HP-5046), which need Genie Product Support approval before use (1307785GT p.2 and the hydraulic oil pages of the other books). An oil cooler may be needed if fluid temperature consistently exceeds 200 F (90 C).

Batteries and engines

ModelDrive batteriesEnginePage
Z-45/25 ICnone (12V starting battery)Spec pages for Deutz D2011 L03i, Deutz D 2.9 L4 and Kubota D1105-E4B1312350GT pp.9-11
Z-45/25J DC8 x 6V DC, group L-16, 350AH, 750 min reserve at 25Anone1315848GT p.1
Z-45/25 Bi-Energy8 x 6V DC, group L-16, 350AH, 750 min reserveKubota Z482-E2B or Z482-E3B, 13.3 hp at 3600 rpm, oil 2.2 qt (E2B) or 2.6 qt (E3B); generator 54V DC, 100A at 3000 rpm1268546GT pp.1, 6-7
Z-60 DC and FE8 x group 903-L16: Trojan lead acid L16G-AC 390AH, or AGM (Fullriver 415AH, Trojan 370AH)Kubota D1105-E4-GNI-1, 24.8 hp gross at 3000 rpm, oil 5.4 qt (5.1 L); or Kohler KDW14041307785GT pp.1, 6-7

Engine and generator notes

The Kubota D1105 on the Z-60 FE runs a 2150 rpm low idle and 3000 rpm high idle, holds 3.3 qt (3.1 L) of coolant, ships with 15W-40 (10W-30, 10W-40 or 15W-40 by temperature per the chart), uses one 12V Group 70 battery of 75AH, and drives through an electric clutch rated 1.6A at 48V DC, 29.22 ohms plus or minus 5% (1307785GT p.6). The Bi-Energy Kubota Z482 is a two cylinder engine with a 2000 rpm low idle and 3000 rpm high idle and a 12V Group 70 starting battery. Its generator should give 54V DC at 100A with the engine at 3000 rpm; the generator pulley must sit within 1/16 inch (1.6 mm) of the engine pulley and the belt deflect no more than 1/4 inch (6.5 mm). The generator pulley retaining nut takes 80 to 90 ft-lb (108 to 122 Nm) and the engine pulley bolts 108 in-lb (12.2 Nm) (1268546GT pp.6-7). On the Z-45/25 IC the maximum stowed drive speed is 4.5 mph with the Deutz engines and 3.1 mph with the Kubota D1105-E4B (1312350GT p.3).

Function and drive speeds from the platform controls

FunctionZ-45/25 IC (1312350GT p.3)Z-45/25J DC (1315848GT p.1)Z-60 DC and FE (1307785GT p.2)
Primary boom up24 to 28 s32 to 40 s36 to 44 s (secondary fully raised)
Primary boom down24 to 28 s26 to 30 s36 to 44 s (secondary fully raised)
Primary boom extend18 to 22 s12 to 20 s42 to 52 s
Primary boom retract18 to 22 s15 to 23 s34 to 42 s
Secondary boom up24 to 28 s38 to 46 s31 to 39 s
Turntable rotate355 degrees: 62 to 68 s355 degrees: 95 to 125 sper 90 degrees: 21 to 27 s stowed, 35 to 42 s not stowed
Drive, stowed4.5 mph Deutz; 3.1 mph Kubota3 mph (40 ft in 9 s)4.0 mph (40 ft in 6.8 s)
Drive, raised or extended0.6 mph (40 ft in 45 s)0.6 mph (40 ft in 45 s)0.7 mph (40 ft in 40 s)
Braking distance, high range, paved3 to 6 ft5 to 7 ft3 to 6 ft

Bi-Energy speeds and torque values

The Bi-Energy Z-45/25 matches the DC machine on drive speed (3 mph stowed, 0.6 mph raised) and braking (5 to 7 ft), with primary boom up 32 to 40 seconds, extend 14 to 18 seconds and platform rotate 6 to 10 seconds (1268546GT p.1). Its torque table gives the platform rotator 3/4-10 center bolt, GR 8, at 380 ft-lb (515 Nm) and the 3/8-16 bolts at 44 ft-lb (60 Nm); the turntable rotate bearing mounting bolts at 180 ft-lb (244 Nm) lubricated; the drive motor and brake mounting bolts at 110 ft-lb (149 Nm) dry or 80 ft-lb (108 Nm) lubricated; the drive hub mounting bolts at 180 ft-lb (244 Nm) lubricated; and the drive motor mounting bolts at 55 ft-lb (75 Nm) lubricated (p.6). The IC book also lists machine component weights for lifting: the primary boom assembly is 946.8 lb (429.5 kg), the secondary boom assembly 1679.6 lb (761.9 kg), the counterweight 2875 lb (1304 kg), the turntable without counterweight 3145 lb (1426.5 kg) and the drive chassis 4950 lb (2245.3 kg) (1312350GT p.2).

Load cell calibration on the Z-60 DC and FE

For the full load platform calibration Genie has you perform a zero load calibration first, then place a test weight of 500 lb (227 kg) on the platform floor near the center entry point, as far from the operator controls as possible, or pull the same reading on a hanging scale under the platform with a winch or chain hoist. Hold secondary boom up for 3 to 4 seconds: the hour meter shows MAXRATED LOAD CAL OK when the calibration is saved, or MAXRATED LOAD OUT OF RANGE if it was not, in which case adjust the load cell and repeat (1307785GT pp.28-29). The same book has procedures to reset calibration defaults from the platform, calibrate the boom angle sensors, check the function pump calibration and calibrate the universal tilt and steer angle sensors (contents, pp.16, 23, 45, 63, 65). Code 76-17 (load cell not calibrated, or only the zero load done) means the full calibration still has to be run (p.78).

Codes you will see most on a Z-45/25 or Z-60

Machine and codeMeaningWhat the manual saysPage
Z-45/25 IC, 51-17Drive joystick not calibratedSpeed and direction frozen at zero and neutral; calibrate the joystick1312350GT p.83
Z-45/25 IC, 81-21Platform load sense overloadLimited speed, direction frozen, alarm; self-clearing1312350GT p.83
Z-45/25 IC, 82-21Load sense overload recoveryLimits primary up, secondary up and primary extend; self-clearing after timeout1312350GT p.83
Z-45/25J DC, 41LOW BATTERY: supply to the motor controller below 32V DCMachine will not drive; fully charge, check cables and terminals1315848GT p.53
Z-45/25J DC, 42OVERVOLTAGE: above 55V DC or charger plugged inMachine will not drive; unplug the charger, check cables1315848GT p.53
Z-45/25J DC, 43THERMAL CUTBACK: outside -13 F to 185 F, excessive load or poor coolingMachine will not drive; check for debris around the controller1315848GT p.53
Z-60 DC/FE, 76-23Platform load value too high: overload detectedAll functions disabled; remove excess weight1307785GT p.78
Z-60 DC/FE, 131-24Battery voltage too lowCharging disabled, brake set, main contactor open, no drive; charge and check batteries and cables1307785GT p.83
Z-60 DC/FE, 135-28Wall powered charger timeoutPack did not reach voltage in the time limit; check DC connections, temperature, batteries1307785GT p.83

Reading the codes on each machine

Z-45/25 IC (ALC-500 controller): a fault is present when the platform alarm gives two short beeps every 30 seconds for 10 minutes. With the engine off, the key at platform and both Emergency Stops out, open the platform control box and watch the red and yellow LEDs on the ALC-500 board without touching it. The red LED flashes the error source: first digit once per second, a 1.5 second pause, then the second digit once per 0.5 second, with the yellow LED solid. The yellow LED then flashes the error type the same way (1312350GT p.80). Z-45/25J DC and Bi-Energy: the motor controller status indicator light on the left side of the ground control box blinks a two digit code: the first digit, a 1 second pause, then the second digit, with a 2 second pause between codes, so 4 blinks, a pause and 1 blink is code 41 (1315848GT p.50). The chart also gives the matching text on a hand-held programmer. A single blink (code 1) is normal operation, and a light that is off or on but not blinking is a communication error, for example from cycling the key or an Emergency Stop off and on faster than 5 seconds (p.51). Z-60 DC and FE: the ground display smart hour meter shows Genie fault codes with its red LED lit, each for 4 seconds in turn; at the platform, one short beep every 30 seconds means a fault, and the FAULTS menu is reached by holding the drive enable toggle and steer to the right as the display leaves SYSTEM READY (1307785GT pp.70-71). The full lists are on the Genie fault codes page.

Frequently Asked Questions

What batteries are in a Genie Z-45/25J DC?

Eight 6V DC group L-16 batteries rated 350AH with 750 minutes reserve at 25A (1315848GT p.1). The motor controller shows LOW BATTERY (code 41) below 32V DC (p.53).

How much hydraulic oil does a Genie Z-45/25 hold?

The IC machine's tank holds 22 gal (83 L) and the system 30 gal (113.6 L). The DC and Bi-Energy versions hold 8 gal (30.3 L) in the tank and 11 gal (41.6 L) in the system (1312350GT p.2; 1315848GT p.1; 1268546GT p.1).

What is the lug nut torque on a Genie Z-60 DC or FE?

240 ft-lb (325 Nm) dry or 180 ft-lb (244 Nm) lubricated on the 5/8-18 lugs (1307785GT p.1).

How do I read the flash codes on a Genie Z-45/25?

On the IC machine open the platform control box and count the red LED (error source) and then the yellow LED (error type) on the ALC-500 board. Each is a two digit number flashed as one digit, a 1.5 second pause, then the second digit (1312350GT p.80).

What weight calibrates the load cell on a Genie Z-60 DC or FE?

500 lb (227 kg), placed near the center entry point of the platform after a zero load calibration (1307785GT p.29).