SULLAIR-HIGH-TEMPERATURE critical Sullair WS Controller

High Temperature 1/2/3 — Discharge Over-Temperature Fault

The SULLAIR-HIGH-TEMPERATURE (Sullair WS Controller) diesel fault code means: High Temperature 1/2/3 — Discharge Over-Temperature Fault. This is a critical severity code.

My Garage →
Keep driving?
Yes, but fix soon
DIY difficulty
moderate
Built for Diesel — Not a Car Reader
ANCEL HD7000 Heavy-Duty Diesel Scanner

A $30 car code reader can't do diesel. The HD7000 reads full-system codes and does parked DPF regen, idle/speed-limit, and service resets from the cab — on everything from a 6.7 Cummins/Power Stroke/Duramax pickup to Class-8 trucks (Detroit, Paccar, CAT, Volvo, Mack, International).

Check Price on Amazon

Affiliate link -- we earn a commission at no extra cost to you.

Lower-Cost Diesel Option
FOXWELL HD301 Diesel Truck Scanner
FOXWELL HD301 Diesel Truck Scanner

Full-system 6/9/16-pin diesel scan tool for Cummins, Paccar, CAT, Detroit and more — plug-and-play, no subscription. A cheaper way to read heavy-duty codes a basic OBD2 scanner skips entirely.

Check Price on Amazon

Affiliate link -- we earn a commission at no extra cost to you.

Common Symptoms

  • WS display shows High Temperature 1, 2 or 3 and the machine faults (red LED)
  • Compressor shuts down and stays inoperative until cleared

Probable Causes (Ranked by Likelihood)

  • Compressor fluid level low High
  • Cooler fins or tubes dirty / plugged High
  • Thermal valve fault Moderate
  • Low water flow or high water temperature (water-cooled units) Moderate
  • Ambient temperature above 105°F (41°C) Moderate
  • Temperature probe or sensor failure Low

Step-by-Step Diagnostic Procedure

  1. The WS Controller is fitted to Sullair STATIONARY electric shop compressors. Portable towable Sullair units (185-class and similar) use different engine-driven controls and a different fault system — this page does not apply to them.

  2. Replenish compressor fluid to the proper level — the factory list starts there.

  3. Clean the cooler fins and fan blades; on water-cooled machines check for a closed valve, stopped pump or broken pipe, and increase water flow or lower water temperature as needed.

  4. Check thermal valve operation.

  5. If ambient exceeds 105°F (41°C), improve local ventilation.

  6. If the machine is genuinely cool and the fault repeats, check the temperature sensor and its wiring.

  7. Factory limits for this condition: T1 warning 225°F; fault 235°F (time-delayed) / 255°F (immediate)

  8. Per the factory manual: after resolving a fault condition, press the STOP pad to clear the FAULTED state. If the problem persists after the recommended checks, consult your Sullair distributor or factory service.

Frequently Asked Questions

What are the actual temperature limits?

Per the manual's parameter table, air-end discharge temperature (T1) warns at 225°F and faults at 235°F time-delayed or 255°F immediate. A fault lights the red LED and keeps the compressor inoperative until the condition is fixed and STOP is pressed.

Sources

This page is built from documented references. Verify against your own service info before repair work.

Explore More

Was this helpful?

Send this to whoever is fixing the truck — your tech, or the person asking what the fault means.