What does JD-SPN652-FMI5 mean?

The JD-SPN652-FMI5 (John Deere PowerTech) diesel fault code means: Cylinder #2 Injector - Current Below Normal (Open Circuit). This is a serious severity code.

Common Symptoms

  • Rough idle / misfire on cylinder 2
  • Smoke on cold start
  • Loss of power

Probable Causes (Ranked by Likelihood)

  • Broken solenoid wire in valve-cover pass-through Very Likely
  • Failed injector solenoid Likely
  • ECU driver fault Less Likely

Step-by-Step Diagnostic Procedure

  1. Swap-test injector with cyl 1.

  2. Check harness continuity ECU->injector.

Frequently Asked Questions

What is John Deere fault code SPN 652 FMI 5?

On John Deere PowerTech engines, SPN 652 FMI 5 means: Cylinder #2 Injector - Current Below Normal (Open Circuit). Serious code -- address promptly to avoid inducement / further damage.

Can I keep using my John Deere tractor with SPN 652 FMI 5?

Serious fault -- you can move the machine to a shop but don't run it under load. Diagnose with John Deere Service ADVISOR via an EDL v3 / CF3 interface.

How much does it cost to fix John Deere SPN 652 FMI 5?

Repair cost range: $250-$650 injector, $60-$220 harness. Dealer labor on large tractors runs $180-$240/hr in 2026.